Koi Supplies - Koi For Sale - Koi Ponds - Koi Dealer - Koi Pond Supplies - Aquatics Monday, February 06, 2012   |  Home  |  Contact Us  |  Find Us  |   View Cart  |  Items Ordered: Total:
07732 040075
01708 508877

Pond Heating » Heat Exchangers

Secure Online Payments via NETBANX By Optimal Payments

Koi Zone - A Trusted Commerce Website

Find us on Facebook

Koi Feed Notifications

Pond Heat Exchangers 60,000 - 460,000 BTUs

Pond Heat Exchangers

By utilising a heat exchanger you can create the most economical and efficient way to heat a Koi pond.

Linked to a boiler, the heat is transferred to the pond via the heat exchanger. The final selection of a heat exchanger should be ascertained by pond capacity, boiler output, heat retention properties and positioning of equipment.

The output specification of the heat exchanger is the maximum that may be reasonably expected the unit to produce, so it is therefore highly recommended to upgrade to the next output size if in any doubt.

It is important that the correct rated boiler is used for the size and gallonage of the pond and that the flow rates are not exceeded. The maximum flow rates for the primary and secondary circuits are stated on the label fixed on the front of the boiler along with the relevant rating of that specific heat exchanger.

G M Heat Exchangers are manufactured from quality marine grade Type 316 stainless steel,

Each unit undergoes 12 stringent tests during quality control production.

Each unit is tested to 70 p.s.i before leaving the factory and each one is guaranteed for a full 12 months from purchase date, subject to essential conditions are strictly followed during the installation and working life.

All units must be installed vertically. Care must be taken to insure that no chemical residue can enter the heat exchanger when the system is not running. It is recommended to maintain a constant pH between 7.2 – 7.6 to prevent excessive scaling deposits and corrosion.

The secondary flow, which is the heated flow to the pond(usually after filtration), is then connected to the top right and the flow though which transfers the heated water to the pool will be situated at the lower left outlet. All threaded connections are BSP thread.

It is paramount that the unit is installed in an upright position; with the primary and flow connections from the boiler set top and bottom.

BTUsMax Pond SizeMax gphCoils
60,000 3,000 gallons 900 Single Coiled
100,000 5,000 gallons 1,440 Single Coiled
130,000 6,500 gallons 1,860 Single Coiled
170,000 8,500 gallons 2,460 Single Coiled
230,000 11,500 gallons 3,300 Single Coiled
460,000 23,000 gallons 8,580 Double Coiled

Description Price Order
Heat Exchanger 60000 BTUs £ 185.00 Add to Cart
Heat Exchanger 100000 BTUs £ 195.00 Add to Cart
Heat Exchanger 130000 BTUs £ 215.00 Add to Cart
Heat Exchanger 170000 BTUs £ 235.00 Add to Cart
Heat Exchanger 230000 BTUs £ 275.00 Add to Cart
Heat Exchanger 460000 BTUs £ 645.00 Add to Cart
Related items or information of interest we recommend:

1 x Brass 1-in. x 22mm Connector

Brass 1" x 22 mm Connector

This fitting is for the primary flow and return to the boiler.

Two of these fittings will be needed for each heat exchanger one at top and one at bottom. Basically one connected to the flow and the other to return from the boiler.

For use with Single Coiled Units.

Description Price Order
1 x Brass 1-in. x 22mm Connector £ 9.95 Add to Cart
Related items or information of interest we recommend: